Documentation Number MES1A/B-2106qsg PN7137-rev001
Quick Start Guide
Check Package Content
Configure the MES1A/B
1
2
5
6
□ To change the IP Address, Default Gateway or Netmask, type 1.
□ To configure Master/Slave and Serial Interface settings, type 2.
□ Do not change any configuration settings in section 3.
□ To configure Modbus/TCP Settings, type 4.
□ To configure Modbus Master settings, type 5.
□ To save your settings in the MES1A/B, type S.
□ MES1A or MES1B unit
□ Printed version of this MES1A/B Quick Start Guide
□ Printed manual
□ Software CD
Modbus TCP to
Modbus ASCII/RTU
Hardware Installation
Converters
□ Connect the MES1A/B to the network using an Ethernet
cable.
Models: MES1A/MES1B
Modbus Device Installation
□ Connect your PC to the network.
□ Connect a 12 VDC power supply (not included) to the
MES1A/B and apply power. (10 – 30VDC, 3.6 Watts)
□
Connect Modbus device to the serial interface on the
MES1A/B using the correct cabling:
-
MES1A is a DTE: Use a straight through serial cable if
the Modbus device is a DCE; null modem if device is DTE
MES1B: Four-wire for RS-422, two-wire for RS-485, Set
RS-422/485 switch.
-
Software Installation
3
4
□
Your Modbus device should now be operational on the
network.
□ Insert the software CD. It should auto-start into the
installation wizard.
□ Follow the on screen installation wizard to install the
Device Installer software.
□ Software supports Windows 98, Me, 2K, XP, & NT 4.0
LED Status
7
LED
Power
Link
Color/Status
Red
Function
Power applied
Bootup, 10BaseT
100BaseT
MES1A
RS-232 Model
MES1B
RS-422/485 Model
Orange
Green
Discover the MES1A/B on the network
Activity
Green (Blinking)
Orange
Data on the network
Bootup
□ Open the Device Installer software. It should detect the
MES1A/B and display XPort in the third level of the
Devices Tree.
Note: The MES1A/B can be reset (rebooted) by pressing the Reset
switch for one second. Reset switch is accessed through a small hole in
the top of the enclosure.
□ Expand the tree and click the device IP Address.
□ Select the Telnet Configuration tab, then click Connect.
□ Press Enter within five seconds to go into Setup Mode.
Warning: Do not forget your password if used. There is no easy way to
get into the unit for configuration once you forget your password.
International Headquarters: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA
European Headquarters: Westlink Commercial Park Oranmore Co. Galway Ireland
Documentation Number MES1A/B-2106qsg PN7137-rev001
+353 91 792444 Fax +353 91 792445
|
Addonics Technologies Computer Hardware ADSAUSPCB User Manual
AEG Freezer A72900GNW0 User Manual
AGFA Digital Camera DC 730i User Manual
Alpine Headphones SHS N100 User Manual
Altec Lansing MP3 Docking Station Octiv Air User Manual
American Audio DJ Equipment PPA 210 User Manual
Axis Communications Car Video System M7001 User Manual
Behringer Musical Instrument Amplifier LX110 User Manual
Behringer Stereo System XR12 User Manual
Beko Freezer CDA660F User Manual